An IBM Business Partner suggests an IBM System Storage DS8000 to a customer with a SAN
that is now configured with an EMC Symmetrix subsystem disk.
The customer wants to determine if new HBAs and software upgrades are needed on the servers if the EMC storage is replaced by the DS8000 What document must be carefully read to help address the customer’s concerns()
A.IBM System Storage DS8000: Host Systems Attachment Guide
B.DS8000 Interoperability Matrix
C.IBM System Storage DS8000: Introduction and Planning Guide
D.IBM System Storage Solution Handbook
您可能感兴趣的试卷
你可能感兴趣的试题
A customer needs a remote data copy, data migration, and off-site backup solution. The solution cannot impact application performance. The sites are over continental distances.
Which characteristic of DS8700 Global Mirror makes it a good fit for this customer()
A.it provides synchronous mirroring on both sides
B.it can be implemented withoutFlashCopy volumes at the target site
C.with Global Mirror, the Metro Mirror functions can be used over continental distances
D.it has almost no impact on application performance because of its extremely short andadjustable coordination time
A current IBM System Storage DS8000 open systems customer needs a temporary copy of data that will be needed for only 12 hours.
Which DS8000 function best satisfies this requirement()
A.Multiple RelationshipFlashCopy
B.IncrementalFlashCopy
C.FlashCopy SE
D.Data SetFlashCopy
A customer requires an infrastructure to support disaster recovery of critical applications between two remote data centers. One data center is in Tokyo and one is in Beijing. The customer’s Recovery Point Objective (RPO) requires a six-hour window for a bandwidth of 100 MB/s and a new storage system for a total of 4 TB of data. They estimate 100 MB of new data produced hourly.
What data synchronization method would be recommended to meet the requirements()
A.Metro Mirror
B.FlashCopy
C.Global Mirror
D.Snapshot
A customer has no available floor space for expansion and room for only one disk enclosure pair in their DS8700. Four disk enclosure pairs are required to meet the current I/O needs of a data warehousing application. They are only utilizing 10% of their total capacity. Another application workload needs to be added to the system but requires two disk enclosure pairs. The customer is considering SSD and Easy Tier.
Which of the following is the primary function of Easy Tier()
A.reduce power consumption per unit of storage
B.balance the total workload with other DAs
C.automatically moves hot spots to the appropriate resource
D.SANtiering permits more flexibility by adding additional data paths
A customer has an IBM System Storage DS8100 with 128 DDMs and needs to add additional capacity.
What must be verified by the Business Partner during the visit to the computer room()
A.the space for the upgrade to a DS8700
B.the space on the left of the DS8000 for an expansion frame
C.the space on the right of the DS8000 for an expansion frame
D.the space to install additional DDMs in the base frame
A customer asks for the thermal load (BTU/hr) to determine whether their existing cooling system will support the IBM System Storage DS8000.
Where can the sales representative find this information()
A.IBM System Storage DS8000: Introduction and Planning Guide
B.IBM DS8000 Interoperability Matrix on the support page on the web
C.IBM System Storage DS8000: User’s Guide
D.IBM System Storage DS8000: Solution Assurance Guide
A UNIX customer has a Symmetrix DMX that has crashed three times in the past six months, causing data loss. The customer is shopping for an enterprise storage solution to provide point-in- time copy functionality without a fixed relationship to its primaries.
Which IBM solution best meets this customer’s requirements()
A.IBM System Storage DS8700 andVolumeCopy
B.IBM System Storage DS8700 andFlashCopy
C.IBM System Storage DS8700 andFlashCopy with the NoCopy option
D.IBM System Storage DS8700 andFlashCopy with the Persistent option
An international company has a heterogeneous IBM storage environment with two IBM DS8700 systems in a Metro Mirror relationship. They also have a virtualized environment with two SVC clusters in a Global Mirror relationship. The storage administrator complains about the monitoring of copy services.
Which solution should the IBM storage specialist propose for this pain point()
A.System Storage Productivity Center
B.Tivoli Storage Productivity Center for Replication
C.Tivoli Storage Productivity Center for Disk
D.DS8000 Storage Manager
![](https://static.ppkao.com/ppmg/img/appqrcode.png)
最新试题
A customer recently installed new a SAN with an IBM System Storage DS8700 and several open systems servers to address a need for storage consolidation and still provide good response time. They have asked the Business Partner technical representative for the most complete IBM product that would allow them to do performance reporting of the new SAN environment. What is the best solution()
A customer has two DS8000 systems in their environment. One DS8000 has FlashCopy licensed while the other does not. The customer wishes to license FlashCopy on the second DS8000. Which of the following describes the TDA requirement in this situation()
A customer has the following non-virtualized servers: - three Exchange servers, each with 2.8 TB database - five System i Domino servers, each with 2 TB database - 20 TB usable capacitySun/SAP cluster - 70 TB usable capacity of System p requirement - annual growth rate of 12 TB usable capacity per year What is the most cost-effective solution for three years()
IBM Global Mirror is based on which of the following very effective copy services functions()
Which information is required to get the feature activation codes()
A customer wants to collect performance data from a newly installed IBM System Storage DS8700 to determine if the system meets expected benchmarks using their application test data. Which tool best gathers the performance data()
An IBM Business Partner sells an IBM System Storage DS8700 to a customer. Who is responsible for the installation and set up of the storage server()
A storage specialist is explaining to the customer that relational databases need an additional point-in-time copy process to assure data in memory buffers are flushed to disk prior to the hardware based snapshot command being executed. Which IBM software solution provides usable and consistent point-in-time data copies()
A client has bought an IBM System Storage DS8000 and needs to attach a Sun Solaris Host with 2 HBAs via one fabric to 4 I/O ports on the DS8000. The client needs redundant paths to the volumes on the DS8000. What is the maximum number of volumes that can be used on the Solaris host()
An IBM Business Partner has sold a DS5020 and new IBM SAN switches to replace a customer EMC storage infrastructure. The customer dissatisfaction has arisen during the installation because according to the DS5020 interoperability matrix, two HP Proliant servers running Exchange have FC HBAs that are not supported. Which of the following is the most probable cause of the customer dissatisfaction()