A.Mirrors data
B.Redundancy
C.Speed
D.Automatic hot spare
您可能感兴趣的试卷
你可能感兴趣的试题
A.RAID controllers
B.Multiple UPSs
C.Redundant cooling
D.Dual NICs
E.Redundant power supplies
A.Update the antivirus application
B.Install critical update security patches
C.Adjust the software firewall settings
D.Replace the current antivirus program
A.Remove software
B.Run Windows Updates
C.Update drivers
D.Sysprep
A.Replace the second drive with a hot swappable one.
B.Swap the drive boot order in the BIOS
C.Make the second disk active under the disk management tool.
D.Rebuild the array using the hardware RAID tool at boot.
A.Document the process and update the baseline.
B.Test the theory of probable cause and verify with the software vendor.
C.Establish a plan of action to be included in the business impact analysis.
D.Implement the software manufacturer workaround.
A.They must have a trusted SSL certificate
B.They can be authoritative
C.They cannot be load-balanced
D.They can be recursive
E.They require DHCP
A.A total of six NICs: two pairs of teamed NICs for the DMZ and two NICs for the backenddatabase.
B.One NIC can be configured with VLANs for the DMZ and backend database.
C.A total of eight NICs to be teamed with the appropriate VLANs configured for the DMZ andbackend database.
D.A total of four NICs: two NICs for the DMZ and two NICs for the backend database.
A.Network card configuration
B.Remote access procedures
C.Estimated runtime
D.Maximum load
E.Power cord length
A.Original hardware configuration
B.Service manual
C.Service tag
D.Model number
最新试题
There is a power outage and all servers are shut down properly by the uninterruptible power supply(UPS) software. When one of the servers starts up it displays a logical drive failed error. This server has two processors,16GB of memory, and a RAID 5 array with 10 drives. Which of the following is the MOST likely cause?()
Which of the following is a way to protect server operating systems from a short term contractor?()
Which of the following is the BEST support channel for server software and hardware?()
A Windows 2003 Server is no longer able to access its internal SCSI drive. The cables areconnected, the drive has power, and the drive shows up in Device Manager; however, the My Computerwindow does not show the drive that was previously working and formatted with NTFS. Which of the following would be the FIRST step in regaining access to the drive? ()
Which of the following RAID arrays should be used to achieve the MOST performance?()
Which of the following are examples of physical security measures?()
The operating system partition on a server is nearly out of space on a Windows 2003 Server. The administrator notices that the file pagefile.sys is taking up nearly 2GB of space. Which of the following would BEST resolve this problem?()
Which of the following technologies can provide geographically based load balancing with high availability between two web servers with static content?()
A Windows 2003 Server is no longer able to access its internal SCSI drive. The cables areconnected, the drive has power, and the drive shows up in Device Manager; however, the My Computerwindow does not show the drive that was previously working and formatted with NTFS. Which of thefollowing would be the FIRST step in regaining access to the drive? ()
An administrator will replace five current servers. Which of the following is the MOST important to review before installing new servers?()