单项选择题Low compressor head pressure in a refrigeration system can be caused by().

A.insufficient condenser cooling water
B.excessive condenser cooling water
C.air in the refrigeration system
D.excessive refrigerant in the system


您可能感兴趣的试卷

你可能感兴趣的试题

1.单项选择题Which of the problems listed would came the discharge temperature of an R-12 refrigeration compressor to increase?()

A.Thermal expansion valve frozen open
B.Suction gas heat exchanger bypassed
C.Condenser clogged or fouled
D.High pressure cutout switch inoperative

2.单项选择题The usual symptoms of cavitation in a centrifugal pump is ().

A.noise and vibration
B.an increase in discharge pressure
C.an increase in suction pressure
D.lifting of the relief valve

3.单项选择题One cause of high head pressure occurring in a refrigeration system can be ().

A.insufficient cooling water flow to the condenser
B.a low refrigerant charge in the system
C.the liquid valve is open too much
D.high evaporator superheat

5.单项选择题Pitting in the suction areas of a centrifugal pump bronze impeller is usually caused by ().

A.cavitation
B.electrolysis
C.abrasion
D.corrosion

6.单项选择题If the head pressure of a reciprocating refrigeration compressor is excessive, ().

A.the relief valve should open before the high pressure cutout
B.the relief valve should open and allow the excess refrigerant to flow to the receiver
C.the high pressure cutout switch should operate before the relief valve opens
D.you should close in on the suction valve

7.单项选择题A salinity indicator is used to determine the ().

A.cause of salt contamination
B.location of salt water contamination
C.chemical makeup of feed-water
D.level of alkalinity in condensate

8.单项选择题An increasing head pressure in a refrigeration system, without any corresponding change in the cooling water inlet temperature, would probably be caused by ().

A.restriction in refrigerant piping
B.air and non-condensable gases in the condenser
C.water in the refrigerant
D.flooding back of liquid refrigerant from the evaporator

9.单项选择题Which of the following problems could cause the high pressure cutout switch to shut down the compressor in a refrigeration system?()

A.A shortage of liquid refrigerant
B.Excessive frost on the evaporator
C.Excessive condenser cooling water
D.Insufficient condenser cooling water flow

10.单项选择题The general purpose of a heat exchanger is to ().

A.eliminate hot air from the condenser
B.maintain steady pressure in a system
C.heat, or cool one fluid by means of another fluid
D.reduce the engine room temperature in tropical climates