A.cause an alarm condition
B.secure power to the indicator
C.secure power to the monitored device
D.automatically recluse within 10 seconds
您可能感兴趣的试卷
你可能感兴趣的试题
A.Fuel oil service pump discharge
B.Fuel oil strainer
C.Fuel oil heater
D.Fuel oil flow meter
A.maintain even distribution of bearing wear
B.maintain a constant oil temperature
C.maintain a pressurized film between moving surfaces
D.remove entrained water
A.so as to never be integral lube
B.with a sloped bottom
C.only of nonferrous, noncorrosive metals
D.with drain/return lines terminating just above or at the designed normal level
A.is an indication of the amount of noncombustible material present in the oil
B.indicates the quantity of energy released by burning a unit amount of the fuel
C.is useful for determining proper atomization temperatures
D.reflects the overall thermal efficiency of the fuel oil service system
A.point of opening
B.speed of opening
C.lift from its seat
D.all of the above
A.Steel brush
B.Fine emery cloth or steel wool
C.A section of the removed compression ring
D.A case hardened scraper
A.improper adjustments
B.contaminated fuel
C.coated fuel lines
D.excessive vibration
A.during low loads
B.after proper oil viscosity is reached
C.during starting
D.after cleaning filters
A.adjusts the idle speed control
B.drain and flushes the governor and replace the oil
C.adjusts the compensating needle valve
A.Proper timing
B.Accurate metering
C.Suitable injection rate
D.Suitable atomization rate
![](https://static.ppkao.com/ppmg/img/appqrcode.png)
最新试题
The additional mark ()in the Classification Certificate for Machinery means propulsion apparatus is remotely controlled on the navigating bridge control station, and engine assembly control station is unmanned periodically.
The flash point of a residual fuel oil should be used to determine the highest temperature to which oil may be heated()
If separating effect is not good, which measure should be taken ()
The treatment of the fuel oils involves storage, heating, filtering and()
When does auxiliary burner of incinerator put into operation? ()Ⅰ. start incinerator when it is coldⅡ. the sludge for dealing with is littleⅢ. the sludge for dealing with is largeⅣ. the water and impurity in sludge are too muchⅤ. the temperature in incinerator is lowⅥ. dealing with little solid rubbish
If two A.C.generators are to be operated in parallel, the load is distributed evenly by()
Which of the listed governor characteristics will greatly affect the load sharing relationship between paralleled diesel generators?()
() is not installed on the main switchboar.
Which of the following items don’t belong to dock repair works?()
Thermostatic steam pressure reducing valves are used in the fuel oil service system to control the()