A.continuous running of the compressor
B.high suction pressure
C.high discharge pressure
D.short cycling of the compressor on the water failure switch
您可能感兴趣的试卷
你可能感兴趣的试题
A.the cooling effect of the condensate reduces the compressors efficiency
B.a danger of explosion exists whenever water is present in a compressor
C.water causes erratic operation of pneumatic components
D.the volumetric capacity of the first stage is reduced if water remains
A.the compressor short cycling on high pressure cut out switch
B.high suction pressure
C.high head pressure
D.bubbles in the sight glass
A.The two objects must be in physical contact
B.The two objects must be the same size
C.There must be an existing temperature differential
D.There must be an existing weight differential
A.insufficient lubrication
B.insufficient refrigerant
C.excess refrigerant
D.excessive opening of the expansion valve
A.increase compressor discharge pressure on demand
B.increase compressor operating speed as necessary
C.allow the motor to turn the compressor opposed only by friction
D.reduce the compressor frictional load when starting
A.Radiation
B.Conduction
C.Convection
D.Each of the above
A.Shortage of refrigerant oil
B.Slight shortage of refrigerant
C.Excessive condenser cooling water flow
D.Faulty expansion valve
A.vary their speed according to temperature and load
B.start and come up to speed before air compression begins
C.change speed according to overload demands
D.reduce compressed air charge density
A.radiation
B.conduction
C.convection
D.condo-radiation
A.used in either the fully dosed or fully opened position
B.installed with the stem down
C.used for steam service only
D.used to throttle or regulate the flow of liquid
最新试题
A pressure drop through the refrigerant liquid line may cause ().
The output volume of a positive fixed displacement pump can be changed only by ().
If the relief valve on the discharge side of a hydraulic pump lifts, the cause could be ().
Who is responsible for ensuring that someone is assigned to close the watertight doors in an emergency?()
A salinity indicator is used to determine the ().
The rate of heat transfer between the hot and cold fluids passing through a shell-and-tube type heat exchanger will ().
An increasing head pressure in a refrigeration system, without any corresponding change in the cooling water inlet temperature, would probably be caused by ().
If the head pressure of a reciprocating refrigeration compressor is excessive, ().
The rate of heat transfer from a hot region to a cold region is affected most by the ().
A salinity indicator is used to determine the ().